Rugged, Dependable Design
Automatic Safety Check for grounded test cables
The BCM-44 and BCM-44B are state of the art current monitors designed for continuous operation during bare-hand work. The BCM has an adjustable set point (5 presets also available on BCM-44B) between 1 and 400 microamperes AC or DC. A 90-dB horn sounds an audible warning if this current set point is ever exceeded during use.
The BCM-44 and BCM-44B are extremely rugged and dependable current monitors. Designed for operation a variety of weather conditions, the BCM provides the security needed for bare-hand live-line work.
VON BCM Specifications
BCM
44 |
BCM
44-B |
|
Display
Type |
3-1/2
digit liquid crystal display w/ heater Digits are 0.75 inches (2 cm) |
|
Range |
0-400
microamperes AC or DC 1 microampere resolution |
|
Voltage
Drop |
Less
than 0.5 volts full scale
|
|
Measurement System |
True
RMS within 2% of full scale (400uA) +/- 2 LSD |
|
Set
point(s) |
Adjustable
from 5 to 400 microamperes with a front panel mounted dial |
Front
panel six position switch allows selection of five presets (27, 40, 66, 133, 289 microamperes) or dial adjustable position variable from 5 to 400 microamperes. |
Set
point Accuracy |
Within
two counts
|
|
Audible
Alarm |
Internal
90dB vibrating horn sounds when current exceeds set point, or
when measuring lead is accidentally grounded. |
|
Power Requirements |
12
volts D.C. (24 volts D.C. Optional), negative ground, draws 0.3
A (0.5 A @ 24V)
with horn sounding and 0.06 A under normal operation. |
|
Enclosure |
Precision
die-cast aluminum case 4.72” (12cm) x 8.66” (22cm) x 3.14” (8cm) with external mounting brackets |
Precision
die-cast aluminum case 9” (23cm) x 11” (28cm) x 4.5” (11.5cm) with external mounting brackets |
Weight |
5
Lbs. (2.3kg) |
11
Lbs. (5kg) |
Input
for test |
UHF
coaxial connector |
7
pin Amphenol receptacle with cap |
Input
for Power |
Flange
mounted 3 pin Amphenol receptacle with cap |
Flange
mounted 3 pin Amphenol receptacle with cap |
Test
Cable |
30’
(9.1m) shielded coaxial cable provided |
4’
(1.2m) shielded six conductor cable provided |
Power
Cable |
4’ (1.2m) three conductor cable provided |
4’
(1.2m) three conductor cable provided |
Additional Features of the BCM 44B:
Six-position function switch provides for the following:
1. Meter accuracy check using the internal precision current source
2. Test circuit for boom metering bands
3. Test circuit for hoses
4. Test circuit for leveling rods or fiber optics
5. Total test including the sum of all three circuits
6. Display variable set point
Also a push button is provided to check the continuity of each input
circuit.
Note: Daily use of this monitor does not eliminate the need to perform periodic over-voltage tests on aerial lift devices. The absolute minimum recommended over-voltage test should be a DC test of 2.1 times the line to ground exposure or an AC test of 1.5 times the line to ground exposure.
Printer Formatted specs Approx. 29kB
|
|
|
|
|
|
|
The VON Corporation, P.O. Box 110096, 1038 Lomb Avenue SW
Birmingham, AL 35211 (205)788-2437 |
|